WBM-IIS Whole Body Surface Contamination Monitor

WBM-IIS Whole Body Surface Contamination Monitor

Designed to be installed at the exit of radioactive controlled area of nuclear power plants or associated nuclear facilities, WBM-IIS Whole Body Surface Contamination Monitor is used to monitor body surface for α and β radioactive contamination when workers are leaving the area, so as to detect the contamination and prevent contamination diversion in time.

Product Categories

  •  Measurement type: α/β or β-ray
  • Detector: large area plastic scintillator detector
  • Detector area: hands and feet (1 each): 350×150mm,torso (30 pieces): 200×200 mm
  • Detection efficiency (2π, surface source, protective grid surface): 90Sr-90Y (β): ≥ 30%; 239Pu (α): ≥ 30% ( ≥ 20% for hands and feet)
  • Lower detection limit (meet the confidence level of 95%, environmental background of 0.2 μGy/h, measurement time 10s, protective grid surface): 90Sr-90Y (β):≤ 0.4 Bq/cm239Pu (α):≤ 0.04 Bq/cm2
  • Energy range: 50 keV~6 MeV

Related Products